#Profibus_DP ;===================================================================================== ;==== General DP Keywords ============================================================ ;===================================================================================== GSD_Revision = 5 Vendor_Name = "SOCOMEC" Model_Name = "DIRIS-A40" Revision = "1.00" Ident_Number = 0x0FB8 Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 Hardware_Release = "V1.00" Software_Release = "V1.00" Redundancy = 0 Repeater_Ctrl_Sig = 2 24V_Pins = 0 ;============================================================================== ;==== Supported baudrates ===================================================== ;============================================================================== 9.6_supp = 1 19.2_supp = 1 45.45_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 1 6M_supp = 1 12M_supp = 1 MaxTsdr_9.6=15 MaxTsdr_19.2=15 MaxTsdr_45.45=15 MaxTsdr_93.75=15 MaxTsdr_187.5=15 MaxTsdr_500=15 MaxTsdr_1.5M=20 MaxTsdr_3M=35 MaxTsdr_6M=50 MaxTsdr_12M=95 ;============================================================================== ;==== Slave specific values =================================================== ;============================================================================== Slave_Family = 0@SOCOMEC Implementation_Type = "VPC3+" Freeze_Mode_supp=1 Sync_Mode_supp=1 Fail_Safe=0 Auto_Baud_supp=1 Set_Slave_Add_supp=0 Min_Slave_Intervall=6 Modular_Station=1 Max_Module=19 Modul_Offset=1 Max_Input_Len=244 Max_Output_Len=16 Max_Data_Len=244 Max_Diag_Data_Len=37 ;[Octet:6 (PFB)][[Octet:1 (taille block 1)][Octet:30 (Diag ext block 1)]] ;============================================================================== ;==== User-Prm-Data =========================================================== ;============================================================================== ;126 for our application, 3 for DPV1 Max_User_Prm_Data_Len = 129 Ext_User_Prm_Data_Const(0)= 0x00,0x00,0x00 ;==================================================================================== ;==== Prm-Text-Def-List ============================================================= ;==================================================================================== PrmText=1 ; Boolean Text(0)="FALSE" Text(1)="TRUE" EndPrmText PrmText=3 ; Nominal Frequency Text(0)="50 Hz" Text(1)="60 Hz" EndPrmText PrmText=4 ; Phase rotation Text(0)="V1 - V2 - V3" Text(1)="V1 - V3 - V2" EndPrmText PrmText=5 ; LineI1 : Way Text(0)="Way positive" Text(1)="Way negative" EndPrmText PrmText=8 ; Type Text(0)="Undefined" Text(1)="1P+N-1CT" Text(2)="2P-1CT" Text(3)="2P+N-2CT" Text(4)="3P-1CT" Text(5)="3P-2CT" Text(6)="3P-3CT" Text(7)="3P+N-1CT" Text(8)="3P+N-3CT" EndPrmText PrmText=9 ; Compute method for reactive and apparent powers Text(0)="Arithmetic" Text(1)="Vector" EndPrmText PrmText=10 ; THD type Text(0)="THD (fundamental)" Text(1)="thd (RMS)" EndPrmText PrmText=11 ; THD method Text(0)="Total" Text(1)="Spectrum" EndPrmText PrmText=12 ; THD spectrum limit Text(0)="Rank 40" Text(1)="Rank 63" EndPrmText PrmText=14 ; Type Text(0)="Normally opened" Text(1)="Normally closed" EndPrmText PrmText=15 ; Pulse meter unit Text(0)="Wh" Text(1)="varh" Text(2)="VAh" Text(3)="m3" Text(4)="Nm3" Text(5)="J" Text(6)="Imp" Text(7)="L" Text(8)="Custom Unit" Text(10)="kWh" Text(11)="kvarh" Text(12)="kVAh" Text(13)="km3" Text(14)="kNm3" Text(15)="kJ" Text(16)="kImp" Text(17)="kL" Text(18)="kCustom Unit" Text(20)="MWh" Text(21)="Mvarh" Text(22)="MVAh" Text(23)="Mm3" Text(24)="MNm3" Text(25)="MJ" Text(26)="MImp" Text(27)="ML" Text(28)="MCustom Unit" Text(30)="GWh" Text(31)="Gvarh" Text(32)="GVAh" Text(33)="Gm3" Text(34)="GNm3" Text(35)="GJ" Text(36)="GImp" Text(37)="GL" Text(38)="GCustom Unit" EndPrmText PrmText=16 ; Avg Period Text(1)="1 min" Text(2)="2 min" Text(3)="3 min" Text(4)="4 min" Text(5)="5 min" Text(6)="6 min" Text(10)="10 min" Text(12)="12 min" Text(15)="15 min" Text(20)="20 min" Text(30)="30 min" Text(60)="60 min" EndPrmText ;===================================================================================== ;==== Ext-User-Prm-Data-Def-List ===================================================== ;===================================================================================== ExtUserPrmData=2 "Nominal Voltage" Unsigned32 400 50-400000 EndExtUserPrmData ExtUserPrmData=3 "Nominal Frequency" Unsigned8 0 0-1 Prm_Text_Ref=3 EndExtUserPrmData ExtUserPrmData=4 "Phase rotation" Unsigned8 0 0-1 Prm_Text_Ref=4 EndExtUserPrmData ExtUserPrmData=5 "PT used" Unsigned8 0 0-1 Prm_Text_Ref=1 EndExtUserPrmData ExtUserPrmData=6 "PT rate : primary" Unsigned32 100 50-400000 EndExtUserPrmData ExtUserPrmData=7 "PT rate : secondary" Unsigned16 100 50-520 EndExtUserPrmData ExtUserPrmData=8 "CT1 : primary" Unsigned16 10 5-10000 EndExtUserPrmData ExtUserPrmData=9 "CT1 : way" Unsigned8 0 0-1 Prm_Text_Ref=5 EndExtUserPrmData ExtUserPrmData=10 "CT2 : primary" Unsigned16 10 5-10000 EndExtUserPrmData ExtUserPrmData=11 "CT2 : way" Unsigned8 0 0-1 Prm_Text_Ref=5 EndExtUserPrmData ExtUserPrmData=12 "CT3 : primary" Unsigned16 10 5-10000 EndExtUserPrmData ExtUserPrmData=13 "CT3 : way" Unsigned8 0 0-1 Prm_Text_Ref=5 EndExtUserPrmData ExtUserPrmData=15 "Load type" Unsigned8 8 0-8 Prm_Text_Ref=8 EndExtUserPrmData ExtUserPrmData=16 "Inom" Unsigned16 63 5-10000 EndExtUserPrmData ExtUserPrmData=17 "Inst. period" Unsigned16 5 1-300 EndExtUserPrmData ExtUserPrmData=18 "Avg period" Unsigned16 10 1-60 Prm_Text_Ref=16 EndExtUserPrmData ExtUserPrmData=19 "Compute method for Q/S/PF" Unsigned16 0 0-1 Prm_Text_Ref=9 EndExtUserPrmData ExtUserPrmData=20 "THD type" Unsigned16 0 0-1 Prm_Text_Ref=10 EndExtUserPrmData ExtUserPrmData=21 "THD method" Unsigned16 0 0-1 Prm_Text_Ref=11 EndExtUserPrmData ExtUserPrmData=22 "THD spectrum limit" Unsigned16 1 0-1 Prm_Text_Ref=12 EndExtUserPrmData ExtUserPrmData=24 "Type input #1" Unsigned8 0 0-1 Prm_Text_Ref=14 EndExtUserPrmData ExtUserPrmData=25 "Pulse weight input #1" Signed32 100 1-10000 EndExtUserPrmData ExtUserPrmData=26 "Pulse unit input #1" Unsigned8 6 0-255 Prm_Text_Ref=15 EndExtUserPrmData ExtUserPrmData=28 "Type input #2" Unsigned8 0 0-1 Prm_Text_Ref=14 EndExtUserPrmData ExtUserPrmData=29 "Pulse weight input #2" Signed32 100 1-10000 EndExtUserPrmData ExtUserPrmData=30 "Pulse unit input #2" Unsigned8 6 0-255 Prm_Text_Ref=15 EndExtUserPrmData ExtUserPrmData=32 "Type input #3" Unsigned8 0 0-1 Prm_Text_Ref=14 EndExtUserPrmData ExtUserPrmData=33 "Pulse weight input #3" Signed32 100 1-10000 EndExtUserPrmData ExtUserPrmData=34 "Pulse unit input #3" Unsigned8 6 0-255 Prm_Text_Ref=15 EndExtUserPrmData ExtUserPrmData=35 "Type output #1" Unsigned8 0 0-1 Prm_Text_Ref=14 EndExtUserPrmData ExtUserPrmData=36 "Type output #2" Unsigned8 0 0-1 Prm_Text_Ref=14 EndExtUserPrmData ExtUserPrmData=37 "Custom - MODBUS Addr. Var #1" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=38 "Custom - MODBUS size Var #1" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=39 "Custom - MODBUS Addr. Var #2" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=40 "Custom - MODBUS size Var #2" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=41 "Custom - MODBUS Addr. Var #3" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=42 "Custom - MODBUS size Var #3" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=43 "Custom - MODBUS Addr. Var #4" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=44 "Custom - MODBUS size Var #4" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=45 "Custom - MODBUS Addr. Var #5" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=46 "Custom - MODBUS size Var #5" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=47 "Custom - MODBUS Addr. Var #6" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=48 "Custom - MODBUS size Var #6" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=49 "Custom - MODBUS Addr. Var #7" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=50 "Custom - MODBUS size Var #7" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=51 "Custom - MODBUS Addr. Var #8" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=52 "Custom - MODBUS size Var #8" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=53 "Custom - MODBUS Addr. Var #9" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=54 "Custom - MODBUS size Var #9" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=55 "Custom - MODBUS Addr. Var #10" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=56 "Custom - MODBUS size Var #10" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=57 "Custom - MODBUS Addr. Var #11" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=58 "Custom - MODBUS size Var #11" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=59 "Custom - MODBUS Addr. Var #12" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=60 "Custom - MODBUS size Var #12" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=61 "Custom - MODBUS Addr. Var #13" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=62 "Custom - MODBUS size Var #13" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=63 "Custom - MODBUS Addr. Var #14" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=64 "Custom - MODBUS size Var #14" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=65 "Custom - MODBUS Addr. Var #15" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=66 "Custom - MODBUS size Var #15" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=67 "Custom - MODBUS Addr. Var #16" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData=68 "Custom - MODBUS size Var #16" Unsigned16 0 0-65535 EndExtUserPrmData ; Start at offset 3 because (0 - 2) are used for profibus DPV1 parameters Ext_User_Prm_Data_Ref(3)=2; Nominal Voltage Ext_User_Prm_Data_Ref(7)=3; Nominal Frequency Ext_User_Prm_Data_Ref(8)=4; Phase rotation Ext_User_Prm_Data_Ref(9)=5; PT used Ext_User_Prm_Data_Ref(10)=6; PT rate : primary Ext_User_Prm_Data_Ref(14)=7; PT rate : secondary Ext_User_Prm_Data_Ref(16)=8; CT1 : primary Ext_User_Prm_Data_Ref(18)=9; CT1 : way Ext_User_Prm_Data_Ref(19)=10; CT2 : primary Ext_User_Prm_Data_Ref(21)=11; CT2 : way Ext_User_Prm_Data_Ref(22)=12; CT3 : primary Ext_User_Prm_Data_Ref(24)=13; CT3 : way Ext_User_Prm_Data_Ref(25)=15; Load type Ext_User_Prm_Data_Ref(26)=16; Inom Ext_User_Prm_Data_Ref(28)=17; Inst. period Ext_User_Prm_Data_Ref(30)=18; Avg period Ext_User_Prm_Data_Ref(32)=19; Compute method for Q/S/PF Ext_User_Prm_Data_Ref(34)=20; THD type Ext_User_Prm_Data_Ref(36)=21; THD method Ext_User_Prm_Data_Ref(38)=22; THD spectrum limit Ext_User_Prm_Data_Ref(40)=24; Type input #1 Ext_User_Prm_Data_Ref(41)=25; Pulse weight input #1 Ext_User_Prm_Data_Ref(45)=26; Pulse unit input #1 Ext_User_Prm_Data_Ref(46)=28; Type input #2 Ext_User_Prm_Data_Ref(47)=29; Pulse weight input #2 Ext_User_Prm_Data_Ref(51)=30; Pulse unit input #2 Ext_User_Prm_Data_Ref(52)=32; Type input #3 Ext_User_Prm_Data_Ref(53)=33; Pulse weight input #3 Ext_User_Prm_Data_Ref(57)=34; Pulse unit input #3 Ext_User_Prm_Data_Ref(58)=35; Type output #1 Ext_User_Prm_Data_Ref(59)=36; Type output #2 Ext_User_Prm_Data_Ref(60)=37; Custom - MODBUS Addr. Var #1 Ext_User_Prm_Data_Ref(62)=38; Custom - MODBUS size Var #1 Ext_User_Prm_Data_Ref(64)=39; Custom - MODBUS Addr. Var #2 Ext_User_Prm_Data_Ref(66)=40; Custom - MODBUS size Var #2 Ext_User_Prm_Data_Ref(68)=41; Custom - MODBUS Addr. Var #3 Ext_User_Prm_Data_Ref(70)=42; Custom - MODBUS size Var #3 Ext_User_Prm_Data_Ref(72)=43; Custom - MODBUS Addr. Var #4 Ext_User_Prm_Data_Ref(74)=44; Custom - MODBUS size Var #4 Ext_User_Prm_Data_Ref(76)=45; Custom - MODBUS Addr. Var #5 Ext_User_Prm_Data_Ref(78)=46; Custom - MODBUS size Var #5 Ext_User_Prm_Data_Ref(80)=47; Custom - MODBUS Addr. Var #6 Ext_User_Prm_Data_Ref(82)=48; Custom - MODBUS size Var #6 Ext_User_Prm_Data_Ref(84)=49; Custom - MODBUS Addr. Var #7 Ext_User_Prm_Data_Ref(86)=50; Custom - MODBUS size Var #7 Ext_User_Prm_Data_Ref(88)=51; Custom - MODBUS Addr. Var #8 Ext_User_Prm_Data_Ref(90)=52; Custom - MODBUS size Var #8 Ext_User_Prm_Data_Ref(92)=53; Custom - MODBUS Addr. Var #9 Ext_User_Prm_Data_Ref(94)=54; Custom - MODBUS size Var #9 Ext_User_Prm_Data_Ref(96)=55; Custom - MODBUS Addr. Var #10 Ext_User_Prm_Data_Ref(98)=56; Custom - MODBUS size Var #10 Ext_User_Prm_Data_Ref(100)=57; Custom - MODBUS Addr. Var #11 Ext_User_Prm_Data_Ref(102)=58; Custom - MODBUS size Var #11 Ext_User_Prm_Data_Ref(104)=59; Custom - MODBUS Addr. Var #12 Ext_User_Prm_Data_Ref(106)=60; Custom - MODBUS size Var #12 Ext_User_Prm_Data_Ref(108)=61; Custom - MODBUS Addr. Var #13 Ext_User_Prm_Data_Ref(110)=62; Custom - MODBUS size Var #13 Ext_User_Prm_Data_Ref(112)=63; Custom - MODBUS Addr. Var #14 Ext_User_Prm_Data_Ref(114)=64; Custom - MODBUS size Var #14 Ext_User_Prm_Data_Ref(116)=65; Custom - MODBUS Addr. Var #15 Ext_User_Prm_Data_Ref(118)=66; Custom - MODBUS size Var #15 Ext_User_Prm_Data_Ref(120)=67; Custom - MODBUS Addr. Var #16 Ext_User_Prm_Data_Ref(122)=68; Custom - MODBUS size Var #16 ;============================================================================== ;==== Diagnosis =============================================================== ;============================================================================== ;------------------------------------------------------- ;--- DIAG00 to DIAG05: Status informations (0 to 111) ;------------------------------------------------------- ;0-15 Reserved: Product ID ;16-31 Reserved: Product software version ;32-47 Reserved: Serial_AA_SS ;48-63 Reserved: Serial_SST_L ;64-79 Reserved: Serial_order ;80-111 Reserved: Net ID ;------------------------------------------------------- ;--- DIAG06 - Status Analog alarm (112 to 143) ;------------------------------------------------------- ;136 to 143 byte 1, Status Analog alarm Unit_Diag_Area = 136-137 value(1) = "Status Analog alarm #1 1" value(2) = "Status Analog alarm #1 2" value(3) = "Status Analog alarm #1 3" Unit_Diag_Area_End Unit_Diag_Area = 138-139 value(1) = "Status Analog alarm #2 1" value(2) = "Status Analog alarm #2 2" value(3) = "Status Analog alarm #2 3" Unit_Diag_Area_End Unit_Diag_Area = 140-141 value(1) = "Status Analog alarm #3 1" value(2) = "Status Analog alarm #3 2" value(3) = "Status Analog alarm #3 3" Unit_Diag_Area_End Unit_Diag_Area = 142-143 value(1) = "Status Analog alarm #4 1" value(2) = "Status Analog alarm #4 2" value(3) = "Status Analog alarm #4 3" Unit_Diag_Area_End ;128 to 135 byte 2, Status Analog alarm Unit_Diag_Area = 128-129 value(1) = "Status Analog alarm #5 1" value(2) = "Status Analog alarm #5 2" value(3) = "Status Analog alarm #5 3" Unit_Diag_Area_End Unit_Diag_Area = 130-131 value(1) = "Status Analog alarm #6 1" value(2) = "Status Analog alarm #6 2" value(3) = "Status Analog alarm #6 3" Unit_Diag_Area_End Unit_Diag_Area = 132-133 value(1) = "Status Analog alarm #7 1" value(2) = "Status Analog alarm #7 2" value(3) = "Status Analog alarm #7 3" Unit_Diag_Area_End Unit_Diag_Area = 134-135 value(1) = "Status Analog alarm #8 1" value(2) = "Status Analog alarm #8 2" value(3) = "Status Analog alarm #8 3" Unit_Diag_Area_End Unit_Diag_Area = 120-121 value(1) = "Status Analog alarm #9 1" value(2) = "Status Analog alarm #9 2" value(3) = "Status Analog alarm #9 3" Unit_Diag_Area_End ;122 to 127 byte 3, Status Analog alarm (Reserved) ;112 to 119 byte 4, Status Analog alarm (Reserved) ;------------------------------------------------------- ;--- DIAG07 - Status Logical alarm (144 to 175) ;------------------------------------------------------- ;168 to 173 byte 1, Status Logical alarm Unit_Diag_Area = 168-169 value(1) = "Status Logical alarm #1 1" value(2) = "Status Logical alarm #1 2" value(3) = "Status Logical alarm #1 3" Unit_Diag_Area_End Unit_Diag_Area = 170-171 value(1) = "Status Logical alarm #2 1" value(2) = "Status Logical alarm #2 2" value(3) = "Status Logical alarm #2 3" Unit_Diag_Area_End Unit_Diag_Area = 172-173 value(1) = "Status Logical alarm #3 1" value(2) = "Status Logical alarm #3 2" value(3) = "Status Logical alarm #3 3" Unit_Diag_Area_End ;174 to 175 byte 1, Status Logical alarm (Reserved) ;160 to 167 byte 2, Status Logical alarm (Reserved) ;152 to 159 byte 3, Status Logical alarm (Reserved) ;144 to 151 byte 4, Status Logical alarm (Reserved) ;------------------------------------------------------- ;--- DIAG08 - Status Combination alarm (176 to 207) ;------------------------------------------------------- ;200 to 207 byte 1, Status Combination alarm Unit_Diag_Area = 200-201 value(1) = "Status Combination alarm #1 1" value(2) = "Status Combination alarm #1 2" value(3) = "Status Combination alarm #1 3" Unit_Diag_Area_End Unit_Diag_Area = 202-203 value(1) = "Status Combination alarm #2 1" value(2) = "Status Combination alarm #2 2" value(3) = "Status Combination alarm #2 3" Unit_Diag_Area_End Unit_Diag_Area = 204-205 value(1) = "Status Combination alarm #3 1" value(2) = "Status Combination alarm #3 2" value(3) = "Status Combination alarm #3 3" Unit_Diag_Area_End Unit_Diag_Area = 206-207 value(1) = "Status Combination alarm #4 1" value(2) = "Status Combination alarm #4 2" value(3) = "Status Combination alarm #4 3" Unit_Diag_Area_End ;192 to 199 byte 2, Status Combination alarm (Reserved) ;184 to 191 byte 3, Status Combination alarm (Reserved) ;176 to 183 byte 4, Status Combination alarm (Reserved) ;------------------------------------------------------- ;--- DIAG09 - (207 to 239) ;------------------------------------------------------- ;232 to 239 byte 0, DIAG09 Unit_Diag_Bit(232) = "EN50160 Swell status" Unit_Diag_Bit(233) = "EN50160 Dip status" Unit_Diag_Bit(234) = "EN50160 Interruption status" Unit_Diag_Bit(235) = "Inrush status" ;224 to 231 byte 1, DIAG09 (Reserved) ;216 to 224 byte 2, DIAG09 (Reserved) ;208 to 215 byte 3, DIAG09 (Reserved) ;============================================================================== ;==== Module-Definition-List ================================================== ;============================================================================== Module="F/V/U/I inst " 0x41,0x2F,0x01 1 EndModule Module="F/V/U/I avg " 0x41,0x2F,0x02 2 EndModule Module="P/Q/S/PF Tot. inst " 0x41,0x17,0x03 3 EndModule Module="P/Q/S/PF Tot. avg " 0x41,0x17,0x04 4 EndModule Module="P/Q/S/PF Phase inst " 0x41,0x2F,0x05 5 EndModule Module="P/Q/S/PF Phase avg " 0x41,0x2F,0x06 6 EndModule Module="Unbalance inst " 0x41,0x2B,0x07 7 EndModule Module="Unbalance avg " 0x41,0x2B,0x08 8 EndModule Module="THD/TDD/K-Factor inst " 0x41,0x23,0x09 9 EndModule Module="Total energy " 0x41,0x21,0x0a 10 EndModule Module="Partial energy " 0x41,0x21,0x0b 11 EndModule Module="Multi-fluid feeder " 0x41,0x2f,0x0c 12 EndModule Module="Fresnel " 0x41,0x35,0x0d 13 EndModule Module="Harmonics V " 0x41,0x17,0x0e 14 EndModule Module="Harmonics U " 0x41,0x17,0x0F 15 EndModule Module="Harmonics I " 0x41,0x1F,0x10 16 EndModule Module="Short Custom " 0x41,0x0F,0x11 17 EndModule Module="Long Custom " 0x41,0x3F,0x12 18 EndModule Module="OUTPUT " 0x81,0x0F,0x13 19 EndModule ;============================================================================== ;==== DPV1 KEY WORDS ========================================================== ;============================================================================== DPV1_Slave = 1 C1_Read_Write_supp = 1 C1_Max_Data_Len = 240 ;The parameter specifies the maximum length of user data excluding ;Function_Num, Slot_number, Index, Length, transferred on the ;MSAC_1 communication channel. ;Type: Unsigned8 (0 .. 240) C1_Response_Timeout = 300 Extra_Alarm_Sap_supp = 0 Diagnostic_Alarm_supp = 0 Process_Alarm_supp = 0 Alarm_Type_Mode_supp = 0 WD_Base_1ms_supp = 0 Publisher_supp = 0 C2_Read_Write_supp = 1 C2_Max_Data_Len = 240 ;The parameter specifies the maximum length of user data excluding ;Function_Num, Slot_number, Index, Length, transferred on the ;MSAC_2 communication channel. ;Type: Unsigned8 (0,48 .. 240) C2_Response_Timeout = 300 C2_Max_Count_Channels = 3 Max_Initiate_PDU_Length = 52 ;The parameter specifies the maximum length of an Initiate Request ;PDU including the Function_Num to the Resource Manager. ;Type: Unsigned8 (0,52.. 244) DPV1_Data_Types = 0 Ident_Maintenance_supp = 1 ;I&M functions supported